Type III

The proper servicing and disposal of low-pressure appliances requires Type III certification, but it is important to know that this near-identical exam is different from Type II in that low-pressure systems work in a vacuum. Leak-tests and proper pressurization are an essential component of low-pressure HVAC services.

Progress: 24% (23/94)

Learning progress ?
1. Where would you place a leak detector probe to check gas leaks into the water box with water removed?Not learned2. Which of the following indicates air in a low-pressure system?Not learned3. A hydrostatic tube test kit will:Not learned4. When leak testing a low-pressure centrifugal chiller with nitrogen, what is the maximum test pressure?Not learned5. A rupture disc on a recovery vessel for low-pressure refrigerants relieves at:Not learned6. On low-pressure chillers, moisture most frequently enters the refrigerant system through:Not learned7. Excessive running of a purge system on a low-pressure chiller generally indicates what condition?Not learned8. Pressure relief valves can only be installed:Not learned9. Where should the discharge from a rupture disc be piped for venting?Not learned10. What is the primary purpose of a purge unit on a low-pressure chiller?Not learned11. A company uses a chiller that diverts 55% of its cooling capacity to one of its manufacturing lines and 45% of its cooling capacity to air condition the office spaces. Which leak rate category would this chiller be in?Not learned12. Starting in 2019, what is the leak rate threshold for commercial refrigeration equipment with a full charge of 50 or more pounds of an HCFC refrigerant?Not learned13. Where does refrigerant go after it leaves the purge unit of a low-pressure centrifugal system?Not learned14. To determine if the system is leaking more than the allowable rate, the EPA allows the use of which one of the following methods to determine the full charge?Not learned15. ASHRAE Standard 15-2013 requires the use of room sensors and alarms to detect:Not learned16. Why do chillers using low-pressure refrigerants require purge units?Not learned17. Why should the oil be removed from a low-pressure system at 130°F?Not learned18. The EPA's leak repair requirements apply to appliances with a charge size ofNot learned19. What is meant by the term "high efficiency purge unit?"Not learned20. During evacuation with large amounts of moisture it may be necessary to increase pressure to counteract freezing with gas such as:Not learned21. A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low-pressure chiller is:Not learned22. A chiller with a charge of 200 pounds of an ozone-depleting refrigerant has passed the initial verification leak test. When must a follow-up verification test be conducted?Not learned23. Where is the rupture disc located on a centrifugal chiller?Not learned24. Where is refrigerant added to a centrifugal machine?Not learned25. After all the liquid has been removed from an average 350-ton, low-pressure appliance, approximately how much vapor refrigerant remains in the system?Not learned26. A low-pressure chiller used for comfort cooling must be repaired if it has an annual leak rate of ____ of the total charge.Not learned27. If a strong odor is detected during the recovery process,Not learned28. Where is refrigerant added to a low-pressure system during the charging process?Not learned29. When charging a low-pressure system, refrigerant should be introduced to the system as a vapor to raise the system's saturation temperature to a minimum of;Not learned30. During evacuation of systems with large amounts of water, it may be necessary to;Not learned31. Because a low-pressure system operates below atmospheric pressure (in a vacuum),Not learned32. In a low-pressure chiller, air and other non-condensables collect at the;Not learned33. The most efficient method of leak checking a charged low-pressure refrigeration unit is to;Not learned34. The Standard for machine room safety is;Not learned35. When installing more than one, pressure relief valves must be installed;Not learned36. The EPA-required evacuation level for recovery or recycling equipment used on low-pressure systems isNot learned37. When pressurizing a low-pressure system for leak-detection purposes, do not exceedNot learned38. What type of equipment can be worked on with Type III certification?Not learned39. How long would an equipment owner or operator have to retrofit or retire an appliance that has exceeded the threshold leak rate if the replacement appliance uses 50 pounds or more of an exempt refrigerant?Not learned40. Which of the following best describes the refrigerant recovery process from an R-123 system?Not learned41. What can be used to pressurize a chiller system before opening the system for a non-major repair?Not learned42. The rupture disk on a low-pressure chiller has a burst pressure of;Not learned43. Where is the purge unit located in a low-pressure system?Not learned44. To repair a chiller operating with R-22, the technician;Not learned45. Which of the following refrigerants has a safety classification of B-1Not learned46. Which organization establishes the refrigerant safety group standard?Not learned47. When leak testing a low-pressure chiller, the maximum pressure to use is;Not learned48. The owner must keep records of refrigerant added to a low-pressure system during service and maintenance if the system charge is;Not learned49. Under ASHRAE Standard 34, R-134a is classified as;Not learned50. A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is:Not learned51. A charged low pressure refrigeration system can be efficiently leak checked by:Not learned52. The existence of air in a low pressure system, causes __________.Not learned53. Which safety precaution should be adhered to for low pressure systems?Not learned54. Refrigerant-11 at 14.7 PSIA will boil at about:Not learned55. When there is excessive moisture collecting in the purge unit of a low pressure refrigeration system, this indicates that the __________.Not learned56. ASHRAE Standard 15 - 1994 requires equipment room refrigerant sensors for what safety group classification?Not learned57. When recharging a refrigeration system with R-11, what vapor pressure is necessary in the shells before charging with liquid?Not learned58. After reaching the required recovery vacuum on a chiller, you should:Not learned59. A hydrostatic tube test kit is used to:Not learned60. When charging a chiller, refrigerant vapor is introduced into the system before charging with liquid. This is because:Not learned61. When evacuating a system, the use of too large a vacuum pump can cause:Not learned62. On a low-pressure chiller with an open-type compressor, the ________________ is very susceptible to leaks.Not learned63. What steps may be taken to prevent air accumulation into an idle low pressure refrigeration system?Not learned64. Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ______ percent of the charge per year.Not learned65. When recovering vapor from a low pressure refrigeration system the:Not learned66. Where does refrigerant go after it leaves the purge unit of a low pressure centrifugal system?Not learned67. The purge unit takes its suction from the:Not learned68. Which of the following repairs would ALWAYS be considered "major" under EPA's regulations?Not learned69. Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the:Not learned70. According to the EPA, there is approximately _______ refrigerant vapor left in an average 350 ton R- 11 chiller at 0 psig pressure once all the R-11 liquid has been removed?Not learned71. An oil sample should be taken when __________________.Not learned72. Both CFC-11 and HCFC-123 chillers require purge units because:Not learned73. Refrigerant recovery typically starts with_______ because it is faster.Not learned74. Under EPA's regulations, __________________ is used to pressurize a low-pressure chiller for the purpose of opening the system for a non-major repair?Not learned75. The primary water source for a recovery unit condensing coil is ______.Not learned76. Which statement is NOT true of recycling and recovery equipment manufactured after November 15, 1993?Not learned77. A system does not have to be evacuated all the way to the required level when:Not learned78. Which action listed below is the proper method to reduce refrigerant loss from a purge unit on a CFC-11 chiller?Not learned79. Identify the pressure corresponding to 32F for R-123:Not learned80. What precaution should be taken prior to recovering refrigerant from a chiller suspected of having tube leaksNot learned81. Pressure relief valves must never be:Not learned82. If you are going to removing oil from a low pressure system, you should heat the oil because:Not learned83. After recovering the liquid refrigerant you must:Not learned84. EPA regulations require that any appliances containing more than 50 pounds of refrigerant (except for commercial and industrial process refrigeration) must be repaired when the leak rate exceeds ______ of the charge per year.Not learned85. If you are using a recovery machine manufactured BEFORE November 15, 1993, you must evacuate any low-pressure appliance to ________ before making a major repair:Not learned86. On low pressure chillers, moisture typically enters the refrigerant system through:Not learned87. Refrigerant-11 at a pressure of 17 inches Hg vacuum has a saturation temperature of:Not learned88. The lowest access point on a low pressure centrifugal air-conditioning unit is the:Not learned89. A rupture disc on a recovery vessel for low pressure refrigerants relieves at:Not learned90. According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ______ during a standing vacuum test, the system should be checked for leaks.Not learned91. During chiller evacuation, water is circulated to:Not learned92. When charging an R-410A water chiller, you must first charge with vapor to a pressure of at least _______, before switching to liquid charging.Not learned93. If you leak test a low pressure chiller with nitrogen in excess of 10 psig you could cause the _____________ to fail.Not learned94. ASHRAE Standard 15 - 1994 requires that each machinery room must activate an alarm and mechanical ventilation before refrigerant concentrations exceed:Not learned95. Which repair WOULD NOT fall under the EPA definition for "MAJOR MAINTENANCE, SERVICE, OR REPAIR"?>Not learned96. Refrigerant is added to a centrifugal machine through the:Not learned97. What is meant by the term "high efficiency purge unit?"Not learned98. The PRIMARY purpose of a purge unit on a CFC-11 chiller is to:Not learned99. If you are using a recovery machine manufactured AFTER November 15, 1993, you must evacuate any low- pressure appliance to ________ before making a major repair:Not learned100. If you suspect a leak in the water box of a chiller, you should place the leak detector probe ________________________, and sniff for refrigerants.Not learned101. To determine how much vapor to charge into an evacuated chiller, you should charge with vapor until ____________________.Not learned102. ASHRAE Standard 15 - 1994 requires the use of room sensors and alarms to detect:Not learned103. The discharge from a rupture disc should be piped ____________ for venting?Not learned104. A centrifugal chiller's rupture disk is connected to the chiller'sNot learned105. To remove ice from sight glasses or viewing glasses, use:Not learned106. The maximum test pressure for leak testing a low pressure centrifugal is:Not learned107. According to ASHRAE Standard 34, what is the safety classification of R-123?Not learned108. Excessive running of a purge system on a low pressure chiller generally indicates that the:Not learned109. The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning system is set at ________,Not learned110. During the evacuation of a system containing large amounts of moisture, you can prevent freezing of this moisture by increasing the pressure with _______ gas,Not learned